PA-8016-C3
AWS Specification: AWS A5.5 E8016-C3
JIS Specification: NONE
Other Specification: NONE
I. APPLICATIONS:
Low hydrogen for low temperature welding of line pipes in the field.
II. DESCRIPTIONS:
PA-8016-C3 is a nickel-alloyed electrode designed for the welding of 1%Ni steel or high tensile steel with impact requirements down to -45°C. In addition to its good welding performance in all position, this electrode contains 1%Ni in the weld metal to obtain the qualified impact value and good X-ray performance and usability.
III. NOTES ON USAGE:
-
Pay attention not to exceed proper heat-input because excessive heat-input causes deterioration of impact values and yield strength of weld metal.
-
Preheat at 50-100°C at the postheat at 600-620°C. The preheat temperature varies in accordance with the plate thickness and kind of steels.
-
Dry the electrodes at 350-400°C for about one hour before use
-
Adopt back step method or strike the arc on a small steel plate prepared for this particular purpose to prevent blowholes at the arc starting.
-
Keep the arc as short as possible.
IV. TYPICAL CHEMICAL COMPOSITION OF DEPOSITED METAL (%):
C |
Si |
Mn |
Ni |
0.06 |
0.52 |
0.88 |
0.93 |
V. TYPICAL MECHANICAL PROPERTIES OF DEPOSITED METAL: AT 620°C, 1 HR
Tensile Strength N/mm2 (Ksi) |
Yield Point N/mm2 (Ksi) |
Elongation % |
Impact Value Deg C, J (Deg F, Ft-lbs) |
510 (74) |
590 (86) |
31 |
-46°, 118 (-51°,87) |
VI. WELDING POSITIONS: ALL POSITIONS
VII. SIZES & RECOMMENDED CURRENT RANGE: AC or DC (+)
Diameter (mm) |
|
2.5 |
3.2 |
4.0 |
5.0 |
Length (mm) |
|
350 |
350 |
350 |
350 |
Ampere |
Flat |
55 - 85 |
90 - 130 |
130 - 180 |
180 - 240 |
V & OH |
50 - 80 |
90 - 115 |
110 - 170 |
150 - 200 |