PHiLARC - The No. 1 Choice of Welders

Nickelarc A

AWS Specification : AWS A5.11 E NiCrFe-2

JIS Specification: NONE

Other Specification: NONE

 

I. APPLICATIONS:

Nickelarc A is excellent for overlaying nickel-chromium alloy on steel. More common applications include the welding of 5% and 9% nickel steel transport or storage tanks used for cryogenic products. The chemical or petrochemical industries use.

     Nickelarc  A for many applications such as valve seats and gates, coal gasification and wet process desulphurization equipment.

     II. DESCRIPTION:

Nickelarc A is a nickel-chromium-iron flux-coated electrode designed primarily for shielded metal arc welding of Incoloy® 800 to itself or to 9% nickel steels. This electrode is used for welding a variety of dissimilar wrought or cast forms of carbon steel, austenitic and ferritic stainless steel, and nickel-chromium Inconel® 600 to themselves or to each other. PHILARC Nickelarc A is frequently used for joining Incoloy® 800 to high nickel alloys 200 and 201 or to nickel-copper Monel® 400 and K-500.

     III. NOTES ON USAGE:

  • Preheating is not necessary in general.

  • Avoid the continuous welding if possible. It is effective to weld under 150ºC for reducing cracking tendency.

  • Dry the electrodes at 150 ~ 200ºC for 30 ~ 60 minutes before use.

IV. TYPICAL CHEMICAL COMPOSITION OF WELD METAL (%):

C

Si

Mn

Fe

Ni

Mo

Cr

Nb & Ta

0.04

0.15

2.90

8.05

Bal.

2.24

15.90

2.78

V. TYPICAL MECHANICAL PROPERTIES OF WELD METAL:

Yield Point

N/mm2 (ksi)

Tensile Strength

N/mm2 (ksi)

Elongation

%

Impact Value

°C, J (°F, Ft-Lbs)

628 (91)

399 (58)

43

-196°, 93

(-132, 69)

VI. WELDING POSITIONS: FLAT, FILLET, VERTICAL UP, HORIZONTAL, OVERHEAD

VII. SIZES AVAILABLE AND RECOMMENDED CURRENTS: AC/DC (+)

Size

(mm)

Dia.

3.2

4.0

5.0

Length

350

350

350

Current Range

Flat

70~110

100~150

130~180

Amp

Vertical & OH

65~105

95~140

-

 

 


 

TEST RESULT
 
The information contained or otherwise referenced herein is presented only as “typical” without guarantee or warranty, and Industrial Welding Corporation expressly disclaims any liability incurred from any reliance thereon. Typical data and Test results for mechanical properties, deposit or electrode composition and other properties were obtained from a weld produced and tested according to prescribed standards, and should not be assumed to be the expected results in a particular application or weldment. Actual results will vary depending on many factors, including, but not limited to, weld procedure, plate chemistry and temperature, weldment design and fabrication methods. Users are cautioned to confirm by qualification testing, or other appropriate means, the suitability of any welding consumable and procedure before use in the intended application.